The Importance of Different Implant Surfaces of the Tibial Component for Migration and Adaptive Bone Remodeling in Uncemented Total Knee Arthroplasty (Vanguard Versus Regenerex)

Information source: Hillerod Hospital, Denmark
ClinicalTrials.gov processed this data on August 23, 2015
Link to the current ClinicalTrials.gov record.

Condition(s) targeted: Artrosis of the Knee

Intervention: Vanguard (Device); Regenerex (Device)

Phase: Phase 4

Status: Completed

Sponsored by: Hillerod Hospital, Denmark

Summary

In a prospective randomised study two uncemented tibial components with different coating (Vanguard® porous coating, Biomet and Regenerex® Primary Tibial Tray, Trabecular Metal coating, Biomet) used for total knee arthroplasty (TKA) are evaluated. Both tibial component coatings are designed to provide excellent conditions for bone ingrowth. The differences between the two tibial components are evaluated by measurements of migration of the tibial component assessed by Radiostereometric analysis (RSA) and measurements of the adaptive bone remodeling of the proximal tibial assessed by dual energy X-ray absorptiometry (DEXA).

Clinical Details

Official title: The Importance of Different Implant Surfaces of the Tibial Component for Migration and Adaptive Bone Remodeling in Uncemented Total Knee Arthroplasty (Vanguard Versus Regenerex)

Study design: Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment

Primary outcome: Migration of the tibial component

Detailed description: In general a primary TKA is a durable and well-functioning solution with a 10-year implant survival of more than 90 %. However, new techniques are developed and the patients´ demands for increased durability of the implants are increasing. It is believed that the new implant Regenerex, planned to be tested in the present study, with the new surface coating will facilitate bone ingrowth and secure a better fixation to the host bone, thus increasing the implant survival and improving the function of the prosthesis. One of the implants (Vanguard) has been used for routine clinical use abroad, but also in Denmark for some years, and so far the results have been good. The other type coating (Regenerex) is a micro-casting of the structure of normal trabecular bone, but made from metal alloy, in the element Titanium. Titanium is also very biocompatible (Hoffman 1993, Hahn, H 1970) and have been used with great success in e. g. uncemented total hip arthroplasy for several years (Marshall et al. 2004, Meding et al, 2004). Trabecular metal has a porosious structure close to that of normal trabecular bone, and the biomechanical characteristics such as e. g. compressive strength and elastic modulus are very close to that of normal trabecular bone (Krygier et al. 1999, Zardiackas 2001). These characteristics are the reason why trabecular metal within the past decade have been used for production of different orthopedic implants, and the early clinical results so far have been very promising (Bobyn et al. 2004, Nasser & Poggie 2004, Nehma et al. 2004, Nelson et al. 2003). Quantitative measurements of the implant migration and adaptive bone remodeling of the bone close to the implants are generally accepted as suitable methods for an objective evaluation of the effect of joint replacement surgery and have been proposed as mandatory important examinations that must bee performed before new implants are distributed for wide-spread use (Bobyn et al. 2004, Petersen & Schrøder 2004, Østgaard & Nielsen 2004). Very small movements between an implant and the bone can be measured by special RSA X-rays after implantation of small (0. 8-1. 0 mm) Tantalum markers attached to the implant and in the bone (Selvik 1989), while changes in bone mineral or bone mineral density (BMD) of the bone in close relation to the implant can be measured by DEXA (Glüer et al. 1990, Mazess & Barden 1988). Micromovements with migration of the tibial component are seen after both cemented and uncemented TKA during the first postoperative year. Subsequently most implants stabilize, while a minority migrate continuously beyond the first postoperative year (Ryd et al. 1995). The implants that continues to migrate are those with a high risk of later aseptic loosening. Several studies have evaluated the influence of different parameters such as mode of fixation (cemented/uncemented), surface coating e. g. hydroxyapatite, metal alloys, and design of the prostheses on the migration of the tibial component in primary TKA (Ryd 1986), but whether the use of a surface coating of trabecular metal (Titanium) will result in significant differences has not yet been evaluated. In studies using different bone densitometric techniques for measurements of changes in bone mineral of the proximal tibia after primary TKA a significant decrease in BMD is seen in most studies (Hvid et al. 1988, Karbowski et al. 1999, Levitz et al. 1995, Petersen et al.

1995, Regnér et al. 1999). In some of the studies the decrease in BMD reaches 20% - 36%

(Hvid et al. 1988, Levitz et al. 1995, Petersen et al. 1995, Regnér et al. 1999), however, in other studies BMD remains unchaged (Bohr & Lund 1987, Li & Nilsson 2000, Spittlehouse et al. 1999) or shows a minor increase (Petersen et al. 2005).

Eligibility

Minimum age: 18 Years. Maximum age: 70 Years. Gender(s): Both.

Criteria:

Inclusion Criteria: 1. Severe osteoarthrosis of the knee with indication for a TKA. 2. Age between 18 and 70 years. Exclusion Criteria: 1. Diseases affecting the bone metabolism (osteoporosis, Pagets disease, hyperparathyreoidism etc.). 2. Patients estimated not to be able to understand the "Information to patients" papers or do not want to participate in the study. 3. Premenopausal women.

Locations and Contacts

1. Knee Unit Hørsholm, Department of Orthopaedic Surgery, Hillerød Hospital, Denmark, Hillerod 3400, Denmark
Additional Information

Starting date: May 2010
Last updated: September 3, 2013

Page last updated: August 23, 2015