Simultaneous determination of irbesartan and hydrochlorothiazide in human plasma using HPLC coupled with tandem mass spectrometry: Application to bioequivalence studies.

Author(s): Tutunji LF, Tutunji MF, Alzoubi MI, Khabbas MH, Arida AI

Affiliation(s): Faculty of Pharmacy, University of Jordan, Amman, Jordan. l.tutunji@ju.edu.jo

Publication date & source: 2010-03-11, J Pharm Biomed Anal., 51(4):985-90. Epub 2009 Nov 10.

Publication type: Randomized Controlled Trial; Validation Studies

A sensitive, specific and selective liquid chromatography/tandem mass spectrometric method has been developed and validated for the simultaneous determination of irbesartan and hydrochlorothiazide in human plasma. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard losartan were separated on a reverse phase C(18) column (50mmx4mm, 3microm) using water with 2.5% formic acid, methanol and acetonitrile (40:45:15, v/v/v (%)) as a mobile phase (flow rate of 0.70mL/min). Irbesartan and hydrochlorothiazide were ionized using ESI source in negative ion mode, prior to detection by multiple reaction monitoring (MRM) mode while monitoring at the following transitions: m/z 296-->269 and m/z 296-->205 for hydrochlorothiazide, 427-->175 for irbesartan. Linearity was demonstrated over the concentration range 0.06-6.00microg/mL for irbesartan and 1.00-112.00ng/mL for hydrochlorothiazide. The developed and validated method was successfully applied to a bioequivalence study of irbesartan (300mg) with hydrochlorothiazide (12.5mg) tablet in healthy volunteers (N=36). Copyright 2009 Elsevier B.V. All rights reserved.

Page last updated: 2010-10-05

-- advertisement -- The American Red Cross
 
Home | About Us | Contact Us | Site usage policy | Privacy policy

All Rights reserved - Copyright DrugLib.com, 2006-2017