DrugLib.com — Drug Information Portal

Rx drug information, pharmaceutical research, clinical trials, news, and more



Effects of inhaled fluticasone propionate and oral prednisolone on lymphocyte beta 2-adrenoceptor function in asthmatic patients.

Author(s): Tan KS, Grove A, Cargill RI, McFarlane LC, Lipworth BJ

Affiliation(s): Department of Clinical Pharmacology, Ninewells Hospital and Medical School, University of Dundee, Scotland.

Publication date & source: 1996-02, Chest., 109(2):343-7.

Publication type: Clinical Trial; Controlled Clinical Trial

The aim of the study was to evaluate the facilitatory effects of inhaled corticosteroid on in vitro parameters of lymphocyte beta 2-adrenoceptor function in asthmatic patients. Serum cortisol level was also evaluated as a measure of systemic bioactivity. Ten (four female) asthmatic subjects were evaluated, mean (SEM) age was 28.6(2.0) years, and FEV1 was 79.9%(8.7) predicted. Single doses of inhaled placebo (PL), fluticasone propionate, 1,000 micrograms (F1000), fluticasone propionate, 2,000 micrograms(F2000), or oral prednisolone, 50 mg(PRED), were given at 10 PM the previous night and measurements were made 10 h later. Values for beta 2-receptor density (logBmax: fmol/10(6)cells) were significantly (p < 0.05) greater than PL with PRED but not with inhaled fluticasone (as means and 95% confidence interval [CI] for difference vs PL): PL, 0.27; F1000, 0.30; F2000, 0.32; and PRED, 0.48 (95% CI vs PL, 0.075 to 0.341). Maximal cyclic adenosine monophosphate (cAMP) responses to isoproterenol hydrochloride (isoprenaline (Emax; pmol/10(6)cells) mirrored those for Bmax: PL, 4.00; F1000, 4.68; F2000, 4.26; and PRED, 7.46 (95% CI vs PL, -0.01 to 6.91). Receptor affinity (Kd) was not significantly altered by any treatment. There was significant (p < 0.05) suppression of serum cortisol (nmol/L) with F2000 and PRED compared with PL: PL, 307.9; F1000, 323.2; F2000, 130.1 (95% CI vs PL, 69.76 to 285.8) and PRED, 51.8 (95% CI vs PL, 144.11 to 368.01). Thus, high-dose inhaled fluticasone propionate did not have any facilitatory effects on lymphocyte beta 2-adrenoceptor parameters as compared with oral prednisolone which upregulated beta 2-receptor density and increased cAMP response. In contrast, high-dose inhaled fluticasone (2,000 micrograms) significantly suppressed serum cortisol. In conclusion, there would appear to be a dissociation in systemic sensitivity between effects of inhaled corticosteroid on adrenal suppression and lymphocyte beta 2-adrenoceptor regulation.

Page last updated: 2006-01-31

-- advertisement -- The American Red Cross
 
Home | About Us | Contact Us | Site usage policy | Privacy policy

All Rights reserved - Copyright DrugLib.com, 2006-2017