Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease.

Author(s): Stone GW, Rizvi A, Newman W, Mastali K, Wang JC, Caputo R, Doostzadeh J, Cao S, Simonton CA, Sudhir K, Lansky AJ, Cutlip DE, Kereiakes DJ, SPIRIT IV Investigators

Affiliation(s): Columbia University Medical Center/New York-Presbyterian Hospital and the Cardiovascular Research Foundation, New York, NY 10022, USA. gs2184@columbia.edu

Publication date & source: 2010-05-06, N Engl J Med., 362(18):1663-74.

Publication type: Comparative Study; Multicenter Study; Randomized Controlled Trial; Research Support, Non-U.S. Gov't

BACKGROUND: Previous studies have established the superiority of coronary everolimus-eluting stents over paclitaxel-eluting stents with respect to angiographic findings. However, these trials were not powered for superiority in clinical end points. METHODS: We randomly assigned 3687 patients at 66 U.S. sites to receive everolimus-eluting stents or paclitaxel-eluting stents without routine follow-up angiography. The primary end point was the 1-year composite rate of target-lesion failure (defined as cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization). RESULTS: Everolimus-eluting stents were superior to paclitaxel-eluting stents with respect to the primary end point of target-lesion failure (4.2% vs. 6.8%; relative risk, 0.62; 95% confidence interval, 0.46 to 0.82; P=0.001). Everolimus-eluting stents were also superior with respect to the major secondary end point of the 1-year rate of ischemia-driven target-lesion revascularization (P=0.001) and were noninferior with respect to the major secondary end point of the 1-year composite rate of cardiac death or target-vessel myocardial infarction (P<0.001 for noninferiority; P=0.09 for superiority). The 1-year rates of myocardial infarction and stent thrombosis were also lower with everolimus-eluting stents than with paclitaxel-eluting stents (1.9% vs. 3.1%, P=0.02 for myocardial infarction; 0.17% vs. 0.85%, P=0.004 for stent thrombosis). Target-lesion failure was consistently reduced with everolimus-eluting stents as compared with paclitaxel-eluting stents in 12 prespecified subgroups, except in the subgroup of patients with diabetes (6.4% vs. 6.9%, P=0.80). CONCLUSIONS: Everolimus-eluting stents, as compared with paclitaxel-eluting stents, resulted in reduced rates of target-lesion failure at 1 year, results that were consistent in all patients except those with diabetes, in whom the results were nonsignificantly different. (ClinicalTrials.gov number, NCT00307047.) 2010 Massachusetts Medical Society

Page last updated: 2010-10-05

-- advertisement -- The American Red Cross
 
Home | About Us | Contact Us | Site usage policy | Privacy policy

All Rights reserved - Copyright DrugLib.com, 2006-2017