DrugLib.com — Drug Information Portal

Rx drug information, pharmaceutical research, clinical trials, news, and more



Fetal-maternal hemorrhage detection in Ontario.

Author(s): Lafferty JD, Raby A, Crawford L, Linkins LA, Richardson H, Crowther M

Affiliation(s): Hamilton Regional Laboratory Medicine Program, Hamilton.

Publication date & source: 2003-01, Am J Clin Pathol., 119(1):72-7.

The results from fetal-maternal hemorrhage (FMH) detection and quantitation external quality assessment surveys conducted in Ontario indicate that the rosette test had a sensitivity and specificity for an FMH of more than 10 mL of 1.0 and 0.75, respectively, compared with 0.96 and 0.92, respectively, for acid elution. With FMH quantitation, the percentage error of the mean from the target FMH was 20% or more in 7 of 8 surveys, and coefficients of variation ranged from 39.5% to 71.8%. Inadequate Rho(D) immune globulin prophylaxis could have occurred in 19.4% of the challenges with an FMH of more than 10 mL. The rosette and acid elution techniques are both effective for the detection or exclusion of FMH, but acid elution lacks adequate accuracy and precision for reliable FMH quantitation. Furthermore, a strategy of prescribing an extra 1,500-IU Rho(D) immune globulin dose, in addition to the dose required to treat the volume of fetal blood detected, is an effective strategy to overcome the limitations of FMH quantitation by acid elution.

Page last updated: 2006-01-31

-- advertisement -- The American Red Cross
 
Home | About Us | Contact Us | Site usage policy | Privacy policy

All Rights reserved - Copyright DrugLib.com, 2006-2012