A multicenter, randomized, open-label, comparative, two-period crossover trial of preference, efficacy, and safety profiles of a prefilled, disposable pen and conventional vial/syringe for insulin injection in patients with type 1 or 2 diabetes mellitus.

Author(s): Korytkowski M, Bell D, Jacobsen C, Suwannasari R, FlexPen Study Team

Affiliation(s): Department of Medicine, Endocrinology, and Metabolism, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania 15213, USA. korytkowski@msx.dept-med.pitt.edu

Publication date & source: 2003-11, Clin Ther., 25(11):2836-48.

Publication type: Clinical Trial; Multicenter Study; Randomized Controlled Trial

BACKGROUND: The accuracy and convenience of pen devices for insulin injection have improved quality of life for patients with insulin-treated diabetes mellitus (DM). Prefilled, disposable pens have the advantage of simplicity, with minimal training and attention required and no installation of new cartridges necessary. OBJECTIVE: The aim of this study was to assess patient preference, efficacy, and safety profiles of a prefilled, disposable pen (FlexPen) and conventional vial/syringe injection method for insulin injection therapy among patients with DM. METHODS: In a multicenter, randomized, open-label, crossover study, patients with type 1 or 2 DM were transferred from previous QD or BID conventional insulin therapy to a mixture of 70% insulin aspart protamine suspension and 30% insulin aspart injection (NovoLog Mix 7030) for 4 weeks of dose optimization using their usual type of syringe. Patients were then randomly assigned to use either vial/syringe or a prefilled, disposable pen to inject the biphasic insulin aspart 7030 mixture for the next 4 weeks, followed by 4 weeks of use of the other injection device. Efficacy, safety profiles, and patient preference for the delivery systems were compared. RESULTS: A total of 121 patients (mean [SD] age, 57.0 [12.4] years; age range, 28-81 years; mean [SD] body mass index, 31 [5.5] kg/m(2)) were enrolled. One hundred three patients completed the study. Seventy-four percent of patients (78105) indicated a preference for the pen over the vial/syringe method (95% CI, 71%-87%), compared with 20% (21105) who preferred the vial/syringe. Eighty-five percent (88104) considered the pen more discreet for use in public (compared with 9% [9104] for the vial/syringe), 74% (77104) considered it easier to use overall (compared with 21% [22104] for the vial/syringe), and 85% (89105) found the insulin dose scale on the pen easier to read (compared with 10% [10105] for the vial/syringe). Patients had statistically significant improvement in glycosylated hemoglobin values during the study (P < 0.05). No statistically significant differences in fasting plasma glucose, mean 4-point blood glucose profiles, or serum fructosamine values were found between groups. Overall, the safety profiles during treatment periods with the pen were comparable to those with the vial/syringe. CONCLUSIONS: In this trial, differences in efficacy and safety profiles between the vial/syringe and prefilled, disposable pen appeared negligible. However, more patients expressed a preference to continue use of the pen.

Page last updated: 2006-01-31

-- advertisement -- The American Red Cross

We comply with
HONcode standard.
Verify here.
Home | About Us | Contact Us | Site usage policy | Privacy policy

All Rights reserved - Copyright DrugLib.com, 2006-2008