DrugLib.com — Drug Information Portal

Rx drug information, pharmaceutical research, clinical trials, news, and more



High-performance liquid chromatographic determination of 4-methylpyrazole in plasma and in dialysate.

Author(s): Jobard E, Turcant A, Harry P, Le Bouil A, Allain P

Affiliation(s): Laboratoire de Pharmacologie et Toxicologie, C.H.U., Angers, France.

Publication date & source: 1997-08-01, J Chromatogr B Biomed Sci Appl., 695(2):444-7.

A rapid method for the determination of 4-methylpyrazole (4-MP) levels in plasma and in dialysate by isocratic reversed-phase high-performance liquid chromatography with UV detection is described. The internal standard was the 3-methylpyrazole (3-MP). Plasma sample preparation consisted of a protein precipitation. Dialysate samples were injected without preparation. The method was linear up to 30 mg l(-1) in plasma and up to 5 mg l(-1) in dialysate. The within-day precisions (C.V.) were less than 4% in plasma and were less than 2% in dialysate. The day-to-day precisions (C.V.) were less than 7% in plasma and were less than 3% in dialysate. This method is easy to perform and has practical interest for clinicians who need to monitor in emergency 4-MP levels in ethylene glycol and methanol poisonings.

Page last updated: 2007-05-03

-- advertisement -- The American Red Cross
 