Novel approaches for preventing or limiting events in diabetic patients (Naples-diabetes) trial: a randomized comparison of 3 drug-eluting stents in diabetic patients.

Author(s): Briguori C, Airoldi F, Visconti G, Focaccio A, Caiazzo G, Golia B, Biondi-Zoccai G, Ricciardelli B, Condorelli G

Affiliation(s): Laboratory of Interventional Cardiology and Department of Cardiology, Clinica Mediterranea, Naples, Italy. carlobriguori@clinicamediterranea.it

Publication date & source: 2011-04-01, Circ Cardiovasc Interv., 4(2):121-9. Epub 2011 Mar 1.

Publication type: Comparative Study; Randomized Controlled Trial

BACKGROUND: To expand the paucity of data on the efficacy of various drug-eluting stents in diabetic patients. METHODS AND RESULTS: Type 2 diabetic patients treated in our institution from October 2005 to January 2007 presenting with of de novo lesions in native coronary arteries were randomly assigned to sirolimus-eluting stents (Cypher group; n=76); paclitaxel-eluting stents (Taxus group; n=75); and everolimus-eluting stents (Endeavor group; n=75). Poor metabolic control (HbA1c >7% and low-density lipoprotein cholesterol >100 mg/dL) and microvascular complications (retinopathy and/or nephropathy) were assessed. The primary end point was the 3-year composite of major adverse cardiac events (MACE), including death of any cause, myocardial infarction, and clinically driven target vessel revascularization. MACE-free survival was 86.8% in the Cypher group, 82.5% in the Taxus group, and 64.4% in the Endeavor group (P=0.006 by log-rank test). The post hoc comparisons showed no significant difference between Cypher versus Taxus groups (adjusted P=1.0) but a higher MACE rate in the Endeavor group versus both the Cypher group (adjusted P=0.012) and the Taxus group (adjusted P=0.075). Independent predictors of 3-year MACE at Cox analysis were treatment by Endeavor versus Cypher stent (2.35 [95% confidence interval, 1.07 to 5.41]; P=0.030), multivessel disease (hazard ratio, 1.78 [95% confidence interval, 1.06 to 2.66]; P=0.031), diabetic retinopathy (hazard ratio, 1.60; [95% confidence interval, 1.03 to 2.76]; P=0.038), and poor metabolic control (hazard ratio, 1.60; [95% confidence interval, 1.02 to 2.52]; P=0.048). CONCLUSIONS: The present pilot study suggests that in diabetic patients, the Endeavor stent is associated with a higher 3-year MACE rate when compared with Cypher and Taxus stents. (c) 2011 American Heart Association, Inc.

Page last updated: 2011-12-09

-- advertisement -- The American Red Cross
 
Home | About Us | Contact Us | Site usage policy | Privacy policy

All Rights reserved - Copyright DrugLib.com, 2006-2017